An import is one upload of a data card — it can contain many nights of files. Apnealytics reads those files and turns each calendar day of therapy into a night you can explore.

Supported hardware

Today Apnealytics reads cards from ResMed AirSense and AirCurve machines (AirSense 10/11, AirCurve bilevel). Support for other brands (such as Philips DreamStation) is in active testing but not yet available — those parsers are turned off until they’re calibrated against real cards, so don’t rely on them yet.

Pulling the SD card

1

Power down and eject

Turn the machine off and remove the SD card from the slot on the side of the unit. (On ResMed machines it’s a standard SD card behind a small cover.)
2

Insert it into a reader

Put the card into an SD reader connected to your phone, tablet, or computer.
3

Select the whole card

In Imports, choose the card’s top-level folder. Apnealytics picks up the folder structure (the DATALOG folder of nightly files and the summary file) in one go — you don’t need to hunt for individual files.

What gets read

Your browser uploads the card’s files directly to secure cloud storage. The files never pass through a size-limited server step, which is why large cards upload reliably.
  • At import time, Apnealytics parses only the card’s small nightly summary file (ResMed’s STR.edf, around 120 KB). That’s what populates your nightly rows — AHI, usage, leak, pressure, event composition, and settings — and powers the whole dashboard.
  • Per-night waveform files (the detailed flow, pressure, and event traces, which can be tens of megabytes each) are read only when you open that specific night. This keeps imports fast no matter how big the card is.

How long it takes

Upload time depends on your internet upload speed and how full the card is — the files themselves can total several gigabytes, so a fully loaded card over a slow connection can take a while. Processing into nightly rows, by contrast, is quick because only the small summary file is parsed. The Imports page shows progress and updates as it works, so you can watch it along the way.
Keep the browser tab open until the upload reports complete. If you close it mid-upload, re-run the import — see re-importing below.

Re-importing

You can import the same card again whenever you like — for example after a few more nights of therapy, or if an upload was interrupted. Re-importing the same nights updates them rather than creating duplicates, so it’s safe to re-run an import to catch up or recover from a stopped upload.

Troubleshooting

Start the import again and re-select the same card folder. Already-recorded nights are updated in place, so re-running won’t duplicate your history.
Make sure you selected the top-level card folder, not a single file or a sub-folder. Apnealytics needs the card’s summary file (STR.edf) to build nightly rows; if the card only has loose detail files without the summary, nothing will populate.
Only ResMed AirSense/AirCurve cards are read today. Other brands are in testing and not yet enabled — importing a non-ResMed card won’t produce nights yet.
Glance at the leak for that night first. A high-leak stretch makes AHI, pressure, and other readings unreliable because escaping air distorts what the machine can measure. See Metrics explained.
This is normal on a slower connection — the raw files are large. Upload on a faster/Wi-Fi connection if you can, and leave the tab open; progress is shown as it goes.
Opening a per-night waveform for the first time loads that night’s detail files on demand, so the first open of an older night may take a moment while it fetches and parses in your browser.